West Wise SUD is a small public water system in EPA region 06 that provides tap water for the 76426 zip codes. It has 3 facilities where the water supply was tested for 20 chemical contaminants that impact tap water quality and human health.
1-butanol is a class of Alcohol that has a minimum reporting level of 2 µg/L and a reference level of 700 µg/L. All the latest water samples for West Wise SUD showed levels of 1-butanol that were below unsafe concentration levels. Learn more about 1-butanol.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <2.0 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <2.0 µg/L Below Reporting Level
|
2-methoxyethanol is a class of Alcohol that has a minimum reporting level of 0.4 µg/L and a reference level of 21 µg/L. All the latest water samples for West Wise SUD showed levels of 2-methoxyethanol that were below unsafe concentration levels. Learn more about 2-methoxyethanol.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.4 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.4 µg/L Below Reporting Level
|
2-propen-1-ol (Allyl Alcohol) is a class of Alcohol that has a minimum reporting level of 0.5 µg/L and a reference level of 35 µg/L. All the latest water samples for West Wise SUD showed levels of 2-propen-1-ol (Allyl Alcohol) that were below unsafe concentration levels. Learn more about 2-propen-1-ol (Allyl Alcohol).
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.5 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.5 µg/L Below Reporting Level
|
HAA5 (five regulated haloacetic acids) are a class of Disinfection Byproducts that includes Dibromoacetic Acid, Dichloroacetic Acid, Monobromoacetic Acid, Monochloroacetic Acid, Trichloroacetic Acid and has a minimum reporting level of 0.5 µg/L and a reference level of 60 µg/L. Some (2 of 5 or 40%) of the latest water samples for West Wise SUD showed levels of HAA5 (five regulated haloacetic acids) that were at or above unsafe concentration levels. The maximum reported value was 64.8 µg/L. Learn more about HAA5 (five regulated haloacetic acids).
259 CR 1749 Sample Station Distribution System
| 12/3/2019 63 months ago
| 60 µg/L ☠️ Exceeds Reference Level by 0 µg/L
|
---|---|---|
912 Sunset Lane Sample Station Distribution System
| 12/3/2019 63 months ago
| 53.2 µg/L ⚠️ Exceeds 50% of Reference Level
|
CR3214 @ CR3225 Distribution System
| 12/3/2019 63 months ago
| 64.8 µg/L ☠️ Exceeds Reference Level by 4.8 µg/L
|
FM1655 @ Beaman Blvd. Distribution System
| 12/3/2019 63 months ago
| 51.7 µg/L ⚠️ Exceeds 50% of Reference Level
|
452 CR 3332 Sample Station Distribution System
| 12/3/2019 63 months ago
| 51.5 µg/L ⚠️ Exceeds 50% of Reference Level
|
HAA6Br (six brominated haloacetic acids) are a class of Disinfection Byproducts that includes Bromochloroacetic Acid, Bromodichloroacetic Acid, Dibromoacetic Acid, Dibromochloroacetic Acid, Monobromoacetic Acid, Tribromoacetic Acid and has a minimum reporting level of 0 µg/L and is a potential threat to human health. Learn more about HAA6Br (six brominated haloacetic acids).
259 CR 1749 Sample Station Distribution System
| 12/3/2019 63 months ago
| 35.9 µg/L |
---|---|---|
912 Sunset Lane Sample Station Distribution System
| 12/3/2019 63 months ago
| 33.2 µg/L |
CR3214 @ CR3225 Distribution System
| 12/3/2019 63 months ago
| 36.9 µg/L |
FM1655 @ Beaman Blvd. Distribution System
| 12/3/2019 63 months ago
| 36.7 µg/L |
452 CR 3332 Sample Station Distribution System
| 12/3/2019 63 months ago
| 33.1 µg/L |
HAA9 (nine haloacetic acids) are a class of Disinfection Byproducts that includes Bromochloroacetic Acid, Bromodichloroacetic Acid, Chlorodibromoacetic Acid, Dibromoacetic Acid, Dichloroacetic Acid, Monobromoacetic Acid, Monochloroacetic Acid, Tribromoacetic Acid, Trichloroacetic Acid and has a minimum reporting level of 0 µg/L and is a potential threat to human health. Learn more about HAA9 (nine haloacetic acids).
259 CR 1749 Sample Station Distribution System
| 12/3/2019 63 months ago
| 89.9 µg/L |
---|---|---|
912 Sunset Lane Sample Station Distribution System
| 12/3/2019 63 months ago
| 81.2 µg/L |
CR3214 @ CR3225 Distribution System
| 12/3/2019 63 months ago
| 95.9 µg/L |
FM1655 @ Beaman Blvd. Distribution System
| 12/3/2019 63 months ago
| 82.7 µg/L |
452 CR 3332 Sample Station Distribution System
| 12/3/2019 63 months ago
| 79.5 µg/L |
alpha-hexachlorocyclohexane is a chemical contaminant that has a reference level of 0.006 µg/L. All the latest water samples for West Wise SUD showed levels of alpha-hexachlorocyclohexane that were below unsafe concentration levels. Learn more about alpha-hexachlorocyclohexane.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.01 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.01 µg/L Below Reporting Level
|
Butylated Hydroxyanisole is a chemical contaminant that is a potential threat to human health. Learn more about Butylated Hydroxyanisole.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.03 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.03 µg/L Below Reporting Level
|
chlorpyrifos is a chemical contaminant that has a reference level of 2 µg/L. All the latest water samples for West Wise SUD showed levels of chlorpyrifos that were below unsafe concentration levels. Learn more about chlorpyrifos.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.03 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.03 µg/L Below Reporting Level
|
dimethipin is a chemical contaminant that has a reference level of 140 µg/L. All the latest water samples for West Wise SUD showed levels of dimethipin that were below unsafe concentration levels. Learn more about dimethipin.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.2 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.2 µg/L Below Reporting Level
|
ethoprop is a chemical contaminant that has a reference level of 1.14 µg/L. All the latest water samples for West Wise SUD showed levels of ethoprop that were below unsafe concentration levels. Learn more about ethoprop.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.03 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.03 µg/L Below Reporting Level
|
Germanium is a chemical contaminant that is a potential threat to human health. Learn more about Germanium.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.3 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.3 µg/L Below Reporting Level
|
Manganese is a chemical contaminant that has a reference level of 300 µg/L. All the latest water samples for West Wise SUD showed levels of Manganese that were below unsafe concentration levels. The maximum reported value was 5 µg/L. Learn more about Manganese.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| 3.4 µg/L Meets Reporting Threshold
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| 5 µg/L Meets Reporting Threshold
|
o-toluidine is a chemical contaminant that is a potential threat to human health. Learn more about o-toluidine.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.007 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.007 µg/L Below Reporting Level
|
oxyfluorfen is a chemical contaminant that has a reference level of 200 µg/L. All the latest water samples for West Wise SUD showed levels of oxyfluorfen that were below unsafe concentration levels. Learn more about oxyfluorfen.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.05 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.05 µg/L Below Reporting Level
|
profenofos is a chemical contaminant that has a reference level of 0.3 µg/L. All the latest water samples for West Wise SUD showed levels of profenofos that were below unsafe concentration levels. Learn more about profenofos.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.3 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.3 µg/L Below Reporting Level
|
quinoline is a chemical contaminant that has a reference level of 0.01 µg/L. All the latest water samples for West Wise SUD showed levels of quinoline that were below unsafe concentration levels. Learn more about quinoline.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.02 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.02 µg/L Below Reporting Level
|
tebuconazole is a chemical contaminant that has a reference level of 190 µg/L. All the latest water samples for West Wise SUD showed levels of tebuconazole that were below unsafe concentration levels. Learn more about tebuconazole.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.2 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.2 µg/L Below Reporting Level
|
Total Permethrin is a chemical contaminant that has a reference level of 3.344 µg/L. All the latest water samples for West Wise SUD showed levels of Total Permethrin that were below unsafe concentration levels. Learn more about Total Permethrin.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.04 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.04 µg/L Below Reporting Level
|
tribufos is a chemical contaminant that has a reference level of 0.6 µg/L. All the latest water samples for West Wise SUD showed levels of tribufos that were below unsafe concentration levels. Learn more about tribufos.
Treatment Plant Lab Sink - Post Treatment Treatment Plant
| 12/3/2019 63 months ago
| <0.07 µg/L Below Reporting Level
|
---|---|---|
Walnut Creek Purchase Meter Consecutive Connection
| 12/3/2019 63 months ago
| <0.07 µg/L Below Reporting Level
|
Facility Name | Water Type/Source |
---|---|
Treatment Plant | Surface Water (SW) |
Consecutive Connection | Surface Water (SW) |
Distribution System | Surface Water (SW) |
The latest water samples were taken on December 3rd, 2019.